ALCA CHECK [BN]

Features:
- measuring range :
- alcalinity (BN) 0-60BN
- measuring time : about 20 min
- accuracy : ± 1 BN
- size : 73 mm by 113 mm
- weight : 500 grams
- just one reagent for each test
- easy to use
- quick to apply
- operationally effective
This so called "alcaline reserve" in the lubrication oil should be regulary controlled to avoid engine damages.
The unit for measuring the alcaline reserve is the Base Number. (BN) formerly known also as Total Base Number (TBN). An apprecation of this level enables the engineer to have close control over the condition of the system oil. The determination of Base No. (BN) is simple using MARTECHNIC® equipment and the test will show accurate results within 20 minutes.
In case you have not the right BN chart in your hands you could do the test once with a fresh oil sample as reference before you start the first test with a used oil. You will get the actual BN with following calculation:
|
|||||||||
Take the BN (fresh oil) from the lube oil data sheet - provided from the respective lubeoil supplier.